CQ 3
Black Copy
No copy defect sample is needed.
Definition
The entire
copy is black and there is no
Image.
Probable Cause
Corrective Action
1. Exposure lamp does not light.
1.
Go to the
CQ
27 Exposure RAP.
2.
Reversed connections to the illumination
2. Go
to the circuit diagram in the
CQ 27
sensor.
Exposure RAP and check the wiring to the
illumination sensor.
8/96
CQ 3 Black Copy
3-30
251 0/2515