Switching Between Local And Remote - YASKAWA L1000V Technical Manual

200/400 v classes: 4.0 to 15 kw
Hide thumbs Also See for L1000V:
Table of Contents

Advertisement

n
Setup Group Parameters
Table 4.3
lists parameters available by default in the Setup Group.
If a parameter that needs to be edited is not displayed in the Setup Group, access the parameter through the Programming
Mode.
Parameter
A1-02
Control Method Selection
b1-02
Speed Reference Selection
b1-03
Stopping Method Selection
C1-01
Acceleration Ramp 1
C1-02
Deceleration Ramp 1
C6-02
Carrier Frequency Selection
d1-01
Speed Reference 1
d1-02
Speed Reference 2
d1-03
Speed Reference 3
d1-04
Speed Reference 4
d1-17
Jog Frequency Reference
Note: Parameter availability depends on the control mode set in A1-02. The parameters listed above are available for the default control
mode.
u Switching Between LOCAL and REMOTE
LOCAL mode is when the drive is set to accept the Up/Down command from the LED operator keys. REMOTE mode is
when the drive is set to accept the Up/Down command from an external device (via the input terminals or serial
communications, etc.).
Switch the drive between LOCAL and REMOTE using the LO/RE key on the digital operator or via a digital input
programmed with this function. The LO/RE key is disabled by default, but can be enabled through parameter o2-01.
Note: 1. After selecting LOCAL, the LO/RE light will remain lit.
2. The drive will not allow the user to switch between LOCAL and REMOTE during run.
n
Using the LO/RE Key on the LED Operator
1.
Turn on the power to the drive. The initial display appears.
Press
. The LO/RE light will light up. The drive is now in LOCAL.
2.
To set the drive for REMOTE operation, press
YASKAWA EUROPE SIEP
Table 4.3 Setup Group Parameters
Name
Step
again.
YASKAWA AC Drive L1000V Technical Manual
4.3 The Drive and Programming Modes
Parameter
E1-01
Input Voltage Setting
E1-04
Maximum Output Frequency
E1-05
Maximum Voltage
E1-06
Base Frequency
E1-09
Minimum Output Frequency
E1-13
Base Voltage
E2-01
Motor Rated Current
E2-04
Number of Motor Poles
E2-11
Motor Rated Power
H4-02
Analog Output Terminal AM Gain
L1-01
Motor Overload Protection Selection
Name
Display/Result
75
4