Single cylinder ohv air-cooled engines
Table of Contents

Advertisement

2. Operate rocker switch and observe meter
readings.
3. The meter should show maximum or very
low resistance as the switch is moved
back and forth. Replace the switch if it
remains open or closed in both positions.
NOTE:
(185430-0099-01 ) is wired with
components supplied by the OEM. Contact the
OEM for wiring diagrams and service
information.
2
Stop Switch Adjustments (161400)
1. Move remote speed control to the
position.
2. The governor control lever should not ([A]
Fig. 42) make contact with the stop switch
tang.
3. Move the remote to the
The engine governor control lever tab
should be contacting the stop switch tang
([B] Fig. 43).
50
FA ST
Fig. 42
po sition.
STOP
Fig. 43
If control lever does not contact stop switch
tang:
• Check control cable for adjustment or
binding. Adjust as required or replace
worn parts as needed.
• Be sure the stop switch is firmly
anchored in control bracket. Replace
switch if it cannot be anchored securely.
Key & Interlock Switches
Troubleshoot ing Interlock Switch (104700)
1. Disconnect interlock switch wires from
spade termin als of switch.
2. Set meter to read Ohms. See Figure 8.
3. Connect test leads to two spade terminals
([A] Fig. 44) of swi tch. There should be no
continuity.
Fig. 44
4. Push switch lever in until switch clicks.
Meter should read continuity.
Troubleshoot ing Five-Termina l Key Switch
1. Disconne ct wires from key switch.
2. Set meter to test for continuity. See Figure
8.
3. Check continuity between terminals with
switch in
OFF, RUN
per Key Switch Continuity Chart.
and
positions
START

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents