10 Amp Regulated Alternator - Briggs & Stratton Vanguard 05000 Manual

Single cylinder ohv air-cooled engines
Table of Contents

Advertisement

2
3. Attach BLACK test lead clip to engine
ground.
AC output should be no less than 40VAC @3600
RPM.
If
is found:
no or low output
• Replace stator.
9 Amp DC Outp ut Test
When testing regulator–rectifier for amperage
output, a 12 volt battery with a minimum charge
of 5 volts is required. There will be no charging
output if battery voltage is below 5 volts.
CAUTION: Connect test leads before starting
engine. Be sure connections are secure. If a test
lead vibrates loose while engine is running,
regulator-rectifier may be damaged.
1. Set meter. See Figure 11.
2. Attach RED test lead clip to DC output
terminal ([A] Fig. 21) on regulator–
rectifier.
40
Fig. 20
Fig. 21
3. Attach BLACK test lead clip to positive (+)
battery terminal.
4. Start Engine.
Output should be 3 – 9 Amps @ 3600 RPM.

10 AMP Regulated Alternator

Model 185400
To test alternator output, engine's electrical
system must be connected to a fully charged 12
volt battery.
1. Adjust governor to 3600 RPM for test.
2. Disconnect battery ground cable from
battery negative (-) terminal.
3. Set meter. See Figure 11.
4. Place DC Shunt #
19468
battery post.
5. Install battery ground cable to DC shunt
battery terminal. See Fig. 22
6. Connect multimeter test leads to DC shunt
terminals, RED to RED and BLACK to
BLACK.
7. Start engine.
Output should be approximately 3 amps @ 3600
RPM.
on negative

Hide quick links:

Advertisement

Table of Contents
loading