Chapter 3 Removal and Replacement Procedures
Revision B
RRP1.7 COVER SIDE L (PL1.1.19)
[Removal]
1) Remove the CASSETTE ASSY 250. (RRP2.1)
2) Open the COVER ASSY FRONT MG (PL1.2.1).
3) Open the TRANSFER ASSY (PL6.1.7).
Note: Cover the drum of the DRUM CARTRIDGE to avoid exposure to light.
4) Remove the DRUM CARTRIDGE. (RRP4.6)
Note: The FUSING part is very hot. Take added care not to get burned when performing the
service operation.
5) Remove the FUSER UNIT. (RRP6.1)
6) Remove the two screws (silver, tap,
8mm) that fix the COVER SIDE L
(PL1.1.19) to the printer.
6)
6)
3 - 15
Confidential
Epson AcuLaser C2900N