Epson AcuLaser C2900N Service Manual page 218

Hide thumbs Also See for AcuLaser C2900N:
Table of Contents

Advertisement

Chapter 2 Operation of Diagnostic
- Checking the Sensor and Switch
Sensor Name (Diag. Code)
Manual Feed Sensor
(DI-0)
Tray1 No Paper Sensor
(DI-1)
Epson AcuLaser C2900N
1)
Power on the printer, and enter the Diag Mode.
2)
Execute DI-0.
3)
Insert a sheet into the Manual Feed to check whether the sensor
functions properly.
4)
Confirm that the number shown on the bottom of the display
increases each time the sheet is inserted.
5)
Press the "STOP" key to stop the test.
1)
Power on the printer, and enter the Diag Mode.
2)
Remove the paper from Tray1.
3)
Execute DI-1.
4)
Check whether the sensor functions properly by removing and
replacing the Tray1.
5)
Confirm that the number in the lower section of the display
increases each time the Tray1 is removed and replaced.
6)
Press the "STOP" key to stop the test.
2 - 14
Check Procedure
MiS02003SA
MiS02004SA
Revision B
Confidential

Hide quick links:

Advertisement

Table of Contents