Drawer-Release Latch Replacement - IBM pSeries 630 6C4 Service Manual

Hide thumbs Also See for pSeries 630 6C4:
Table of Contents

Advertisement

Drawer-Release Latch Replacement

To replace one of the Model 6C4 drawer-release latches, do the following:
1. If you have not already done so, open the front rack door and place the system into the service
position as described in "Placing the Model 6C4 into the Service Position" on page 429.
2. Push the release latch onto the latch bracket post.
3. Secure the drawer-release latch onto the latch bracket post with a release latch retaining screw.
4. Push the system drawer back into the operating position as described in "Returning the Model 6C4 to
the Operating Position" on page 430.
Drawer-Release Latch Bracket Removal
To remove the Model 6C4 drawer-release latch brackets, do the following:
1. Open the front rack door and place the system into the service position as described in "Placing the
Model 6C4 into the Service Position" on page 429.
2. Remove the front bezel as described in "Front Bezel Removal (Model 6C4)" on page 442.
3. Remove the release latch as described in "Drawer-Release Latch Removal" on page 427.
4. Remove the retaining screws that secure the latch bracket to the side of the Model 6C4.
1 System Drawer-Release Latch
2 System Drawer-Release Latch
Bracket (Right)
3 Model 6C4
4 System Drawer-Release Latch
Bracket (Left)
428
Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide
5 System Drawer-Release Latch
6 Retaining Screws
7 Release Latch Retaining Screw
8 Latch Bracket Post

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pseries 630 6e4

Table of Contents