IBM pSeries 630 6C4 Service Manual page 299

Hide thumbs Also See for pSeries 630 6C4:
Table of Contents

Advertisement

Table 5. Service Processor Error Codes. (continued)
Error Code Description
4069 0EB6 Attention line 5 stuck fault
4069 0EB7 Attention line 6 stuck fault
4069 0EB8 Attention line 7 stuck fault
4069 0EB9 Attention line 8 stuck fault
4069 0EBA Attention line 9 stuck fault
4069 0EBB Attention line 10 stuck fault
4069 0EBC Attention line 11 stuck fault
4069 0EBF Description: Memory error
Action:
1. Reboot the system in slow mode to the SMS menus. See "Performing Slow Boot" on page 209.
2. Examine the service processor error log.
v If a CEC subsystem error (a 4xxx yyyy error) occurred during the slow boot that calls out the
memory, processors, L3 cache modules or the primary I/O book, replace the part indicated
by the location code.
v If a CEC subsystem error (a 4xxx yyyy error) did not occur during the slow boot, look for a
4xxx yyyy error immediately preceding the 4069 0EBF error. Replace the part indicated by
the location code associated with that error.
4069 0EE1 Service processor firmware: invalid MRU to FRU
mapping
4069 0EE2 Service processor firmware fault
4069 0EE5 Firmware error, no callout available
406A 0001 Scan interface basic assurance tests detected a
CEC backplane fault
406A 0002 CEC backplane fault
406A 0003 Scan interface basic assurance tests detected
processor fault
406A 0004 Processor fault
406A 000E Processor capacity card
Action/
Possible Failing FRU
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
Go to "MAP 1540: Problem Isolation Procedures"
on page 124.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
1. Check for system firmware updates.
2. Call service support.
CEC backplane
Location: U0.1-P1
1. Check JTAG cable connections
2. CEC backplane
Location: U0.1-P1
1. Check JTAG cable connections.
2. Processor card
Location: U0.1-P1-C1
1. Check JTAG cable connections.
2. Processor card
Location: U0.1-P1-C2
Operator Panel
Location: U0.1-L1
Chapter 5. Error Code to FRU Index
279

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pseries 630 6e4

Table of Contents