2. In the Navigation area, double-click the Service Focal Point icon.
3. In the Contents area, click Service Focal Point Settings.
4. The Service Focal Point Settings window opens. Select the CEC Call Home tab at the top of the
window.
5. Click on the managed system you want to enable or disable.
6. Click Enable to enable call-home for the selected system, or click Disable to disable call-home for the
selected system.
7. Click OK.

Setting Up Surveillance

Service Focal Point surveillance generates serviceable events when it detects communication problems
between the HMC and its managed systems.
You can configure how you want the HMC to survey the following:
v The number of disconnected minutes that are considered an outage
v The number of connected minutes you want the HMC to consider a recovery
v The number of minutes between outages that are considered a new incident
To set up surveillance, you must be a member of one of the following roles:
v System Administrator
v Service Representative
To set up surveillance, do the following:
1. In the Navigation area, click the Service Applications icon.
2. In the Navigation area, double-click the Service Focal Point icon.
3. In the Contents area, select Service Focal Point Settings.
4. The Service Focal Point Settings window opens. Select the Surveillance Setup tab on the top of the
window.
5. In the first field, select the number of minutes you want the HMC to wait before sending a
disconnection error message.
6. In the second field, select the amount of connection time that the HMC is considered to be recovered.
This amount is expressed in minutes.
7. In the third field, select the number of minutes between outages that you want the HMC to wait before
sending a new incident report.
8. Select one or more managed systems from the table in the lower part of the window, then click Enable
or Disable. Surveillance is then either enabled or disabled for the selected managed systems.

Enabling Surveillance Notifications

You can enable or disable surveillance-error notification from this HMC to connected managed systems.
Enabling this notification causes errors to be passed to the Service Agent application for notification.
Note: You must further configure Service Agent to handle notifications sent by Service Focal Point. For
more information about Service Agent, refer to the IBM Hardware Management Console Operations
Guide for pSeries, order number SA38-0590
To set up surveillance, you must be a member of one of the following roles:
v System Administrator
v Service Representative
To set up surveillance-error notification, do the following:
1. In the Navigation area, click the Service Applications icon.
2. In the Navigation area, double-click the Service Focal Point icon.
54