Operator Panel Error Codes

Attention:
If you replace FRUs or perform an action and the problem is still not corrected, go to "MAP
1548: Processor Subsystem Problem Isolation" on page 139 unless otherwise indicated in the tables.
If you replace FRUs and the problem is corrected, go to "MAP 0410: Repair Checkout" in the RS/6000
Eserver pSeries Diagnostic Information for Multiple Bus Systems.
Table 1. Operator Panel Error Codes.
Error Code Description
0000 1111 At power on, failure of power-good signal from
power supply.
0000 1112 At power off, failure of power-good signal from
power supply.
0000 1113 While power on, failure of power-good signal
from power supply.
0000 1114 Operator panel and service processor have been
reset after main power disturbance.
0000 2222 Operator panel not communicating with service
processor
0000 3333 SPCN communications error
0000 3334 I2C repeater error
0000 BBBB TOD battery malfunction
216
Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide
Action /
Possible Failing FRU
1. CEC backplane
Location: U0.1-P1
2. CEC backplane power supply
Locations:
U0.1-V1
U0.1-V2
1. CEC backplane
Location: U0.1-P1
2. CEC backplane power supply
Locations:
U0.1-V1
U0.1-V2
1. CEC backplane
Location: U0.1-P1
2. CEC backplane power supply
Locations:
U0.1-V1
U0.1-V2
Information message
1. If system cannot be powered off, reset the
service processor (via the pinhole reset or by
disconnecting then reconnecting power).
2. CEC backplane
Location: U0.1-P1
CEC backplane
Location: U0.1-P1
CEC backplane
Location: UO.1-P1
TOD battery
Location: U0.1-P1-V3