Table 5. Service Processor Error Codes. (continued)
Error Code Description
406D 0010 Memory DIMM fault
406D 0011 Memory DIMM fault
406D 0012 Memory DIMM fault
406D 0013 Memory DIMM fault
406D 0014 Memory DIMM fault
406D 0015 Memory DIMM fault
406D 0016 Memory DIMM fault
406D 0017 Memory DIMM fault
406D 0018 Memory DIMM fault
406D 0019 Memory DIMM fault
406D 001A Memory DIMM fault
406D 001B Memory DIMM fault
406D 001C Memory DIMM fault
406D 001D Memory DIMM fault
406D 001E Memory DIMM fault
406D 001F Memory DIMM fault
406D 00B0 Bus controller failure
406D 00B1 Bus controller failure
406D 00B3 Processor/VPD problem detected
406D 00B4 Processor/VPD problem detected
Action/
Possible Failing FRU
Memory DIMM
Location: U0.1-P1-C1-M8
Memory DIMM
Location: U0.1-P1-C1-M6
Memory DIMM
Location: U0.1-P1-C1-M1
Memory DIMM
Location: U0.1-P1-C1-M3
Memory DIMM
Location: U0.1-P1-C1-M7
Memory DIMM
Location: U0.1-P1-C1-M5
Memory DIMM
Location: U0.1-P1-C1-M2
Memory DIMM
Location: U0.1-P1-C1-M4
Memory DIMM
Location: U0.1-P1-C2-M8
Memory DIMM
Location: U0.1-P1-C2-M6
Memory DIMM
Location: U0.1-P1-C2-M1
Memory DIMM
Location: U0.1-P1-C2-M3
Memory DIMM
Location: U0.1-P1-C2-M7
Memory DIMM
Location: U0.1-P1-C2-M5
Memory DIMM
Location: U0.1-P1-C2-M2
Memory DIMM
Location: U0.1-P1-C2-M4
1. Check for system firmware updates
2. PCI riser card
Location: U0.1-P2
1. Check for system firmware updates
2. PCI riser card
Location: U0.1-P2
3. CEC backplane, U0.1-P1
1. Check for system firmware updates
2. Processor card 1
Location: U0.1-P1-C1
1. Check for system firmware updates
2. Processor card 2
Location: U0.1-P1-C2
Chapter 5. Error Code to FRU Index
295