Error Code Description
B1xx 4603 Service processor firmware corrupted
B1xx 4606 Firmware failure
B1xx 4608 Service processor early termination
B1xx 460A TOD clock has been reset
B1xx 460B TOD battery failure
B1xx 4611 Service processor failure
B1xx 4620 Modem configuration failure
B1xx 4621 Modem disconnect failure
B1xx 4622 Service processor failure
338
Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide
Action/
Possible Failing FRU
1. Reload system firmware
2. CEC backplane
Location: U0.1-P1
1. Check for system firmware updates
2. Operator panel
Location: U0.1-L1
3. CEC backplane
Location: U0.1-P1
1. Reset the system by disconnecting and
reconnecting system power
2. Reload system firmware
3. CEC backplane
Location: U0.1-P1
1. Set TOD clock
2. CEC backplane
Location: U0.1-P1
TOD battery
Location: U0.1-P1-V3
1. Processor card
Location: U0.1-P1-C1
2. CEC backplane
Location: U0.1-P1
1. Check modem configuration files
2. Check for system firmware update
3. Modem
4. CEC backplane
Location: U0.1-P1
1. Check modem configuration files
2. Check for system firmware update
3. Modem
4. CEC backplane
Location: U0.1-P1
1. Operator panel
Location: U0.1-L1
2. Check for system firmware update
3. CEC backplane
Location: U0.1-P1