IPL Flow without an HMC Attached to the System

The IPL process starts when ac power is connected to the system. The IPL process has the following
phases:
v Phase 1: Service Processor Initialization
Phase 1 starts when ac power is connected to the system and ends when OK is displayed in the media
subsystem operator panel. 8xxx checkpoints are displayed during this phase. Several 9xxx codes may
also be displayed. Service processor menus are available at the end of this phase by striking any key
on the console keyboard.
v Phase 2: Hardware Initialization by the Service Processor
Phase 2 starts when system power-on is initiated by pressing the power on button on the processor
subsystem operator panel. 9xxx checkpoints are displayed during this time. 91FF, the last checkpoint in
this phase, indicates the transition to phase 3 is taking place.
v Phase 3: System Firmware initialization
At phase 3, a system processor takes over control and continues initializing partition resources. During
this phase, checkpoints in the form Exxx are displayed. E105, the last checkpoint in this phase,
indicates that control is being passed to the operating system boot program.
v Phase 4: Operating System Boot
When the operating system starts to boot, checkpoints in the form 0xxx and 2xxx are displayed. This
phase ends when the operating system login prompt displays on the operating system console.
The following table outlines the IPL phases from power-on to the operating system login prompt, matching
the phases to corresponding operator-panel checkpoints for a typical partition boot. Also listed are the
approximate boot times for each phase, along with their dependencies for each phase.
Note: The following table lists the major checkpoints only.
Phase #
Checkpoints on Operator
Panel or HMC
Phase 1
8xxx => OK
Phase 2
9xxx => 91FF
Phase 3
Exxx => E105
Phase 4
0xxx or 2xxx => blank
Checkpoints enable users and service personnel to know what the server is doing, with some detail, as it
initializes. These checkpoints are not intended to be error indicators, but in some cases a server could
hang at one of the checkpoints without displaying an 8-character error code. It is for these hang
conditions, only, that any action should be taken with respect to checkpoints. The most appropriate action
is included with each checkpoint.
160
Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide
Time in Phase
Major Contributors to Time in Phase
(minutes)
Approx. 1
3 to 6
Number of I/O drawers
1 to 3
Number of bootable adapters
2 to 30+
Number of SSA drives
Number of SCSI drives
Number of Async sessions
Number of processors
Number of adapters
Amount of memory

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pseries 630 6e4

Table of Contents