IBM pSeries 630 6C4 Service Manual page 263

Hide thumbs Also See for pSeries 630 6C4:
Table of Contents

Advertisement

Table 4. Firmware Error Codes. (continued)
Error Code Description
2602 0002 Description: Invalid PCI adapter device ID
Action:
Attention:
administrator that the slot that the adapter is being moved to is available to the partition in which
the adapter presently resides.
1. Move adapter to another slot (behind a different PCI bus).
2. Check for available firmware updates for adapter. Apply update if available.
3. Run AIX diagnostics on adapter. Replace if indicated.
4. Replace adapter.
5. Check for system firmware updates. Apply if update available.
6. If the card is in the system drawer, replace the PCI riser card, location: U0.1-P2. If the card is
in an I/O subsystem, replace the I/O backplane that contains the slot in which the adapter
was originally installed, location: U0.dd-P1.
2602 0007 Description: PCI device I/O or memory space request could not be satisfied
Action:
1. If the location code identifies a slot:
a. Reseat the adapter and reboot the system.
b. Replace the adapter.
c. Check for system firmware update. Apply update if available.
2. If the location code identifies an I/O planar:
a. Check for system firmware updates. Apply if available.
b. Replace the I/O planar.
3. Call service support.
2602 0008 Description: PCI device Fcode evaluation error
Action:
1. If the location code identifies a slot:
a. Check for adapter firmware updates. Apply if available.
b. Replace the adapter.
c. Check for system firmware updates. Apply if available.
2. If the location code identifies an I/O planar:
a. Check for system firmware updates. Apply if available.
b. Replace the I/O planar.
3. Call service support.
Before moving the adapter to another slot, verify with the customer or system
Action/
Possible Failing FRU
Chapter 5. Error Code to FRU Index
243

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pseries 630 6e4

Table of Contents