IBM pSeries 630 6C4 Service Manual page 115

Hide thumbs Also See for pSeries 630 6C4:
Table of Contents

Advertisement

Step 1321-28
If you performed substep 3 of "Step 1321-24" on page 901321-24 for the current Linux partition, go to
"Step 1321-29", and when asked in "Step 1321-29", do not record any additional extended data from "Step
1321-26" on page 94 for the current Linux partition.
Examine the extended data in both logs.
The following is an example of the Linux extended data.
<3>RTAS daemon started
<3>RTAS: -------- event-scan begin --------
<3>RTAS: Location Code: U0.1-P1-C2
<4>RTAS: Log Debug: 04
4b2726fb04a00011702c0014000000000000000000000000f1800001001801d3ffffffff010000000000000042343138
20202020383030343236464238454134303030303 030303030303030
<4>RTAS: Log Debug: D2
5046413405020d0a000001000271400100000033434d502044415441000001000000000000010000f180000153595
320444154410000000000000000200216271501050920021627150105092002063715010509535243204441544170
2c001400000000000000020018820201d382000000000000000000000000000000000000000000000000000000000
0000000000000000000000000000000000000000000000000000000000000000280048ea400000000000000000000
000000000000000000004350542044415441702cff08000000001c000000702cf0080000000080000000702cf10070
2cf200702c000400000800702c01040bf2002e702c02040c1fffbf702c0300702c1000702c11040bf2002e702c12040
c1fffbf702c1300702ca000702ca108000000000000a03c702ca208000000000000effc702cb000702cb10800000000
0000a03c702cb208000000000000effc702cc000702cc108000000000000a03c702cc208000000000000effc702c3
000702c31080000000000000003702c3208000000000000007b702c8000702c81080000000020e27a39702c820800
000000fffeffff702cd000702cd1080000000010004010702cd208000000007777f3ffffffffffffffffffffffffffffffffffffff
ffffffffffffffffffffffffffff
<3>RTAS: WARNING: (FULLY RECOVERED) type: INTERN_DEV_FAIL
<3>RTAS: initiator: UNKNOWN target: UNKNOWN
<3>RTAS: Status: unrecoverable new
<3>RTAS: Date/Time: 20020905 15372200
<3>RTAS: CPU Failure
<3>RTAS: Internal error (not cache)
<3>RTAS: CPU id: 0
<3>RTAS: Failing element: 0x0000
<3>RTAS: -------- event-scan end ---------
Step 1321-29
Record any extended data found in the Linux system log in Step 1321-24 or the Linux boot (IPL) log in
Step 1321-26. Be sure to record word 13.
Note: The line(s) in the Linux extended data that begin with "<4>RTAS: Log Debug: 04" contain the error
code listed in the next 8 hex characters. In the previous example, "4b27 26fb" is an error code. The
error code is also known as word 11. Each 4 bytes after the error code in the Linux extended data
is another word (for example, "04a0 0011" is word 12, and "702c 0014" is word 13, and so on).
If the system is configured with more than one logical partition with Linux installed, repeat "Step 1321-28"
and "Step 1321-29" for all logical partitions that have Linux installed.
Step 1321-30
Were any error codes or checkpoints recorded in Steps 1321-1, 1321-22, 1321-25, 1321-27, or
1321-29?
No
Go to "Step 1321-31" on page 96.
Yes
Go to the "Quick Entry MAP" on page 63 with each recorded error code or symptom. Perform the
indicated actions one at a time for each error code until the problem has been corrected. If all
recorded error codes have been processed and the problem has not been corrected, go to "Step
1321-31" on page 96.