Description and Action
Request
Number
A03-06x
Description: Mezzanine bus address parity error.
A03-07x
Description: System bus address parity error. Action: Use "MAP 1230: Linux Platform Error
Problem Resolution" on page 80.
A03-08x
Description: Mezzanine bus data parity error. Action: Use "MAP 1230: Linux Platform Error
Problem Resolution" on page 80.
A03-09x
Description: System bus data parity error. Action: Use "MAP 1230: Linux Platform Error
Problem Resolution" on page 80.
A03-10x
Description: Mezzanine bus time-out, transfer or protocol error. Action: Use "MAP 1230:
Linux Platform Error Problem Resolution" on page 80.
A03-11x
Description: System bus time-out error. Action: Use "MAP 1230: Linux Platform Error
Problem Resolution" on page 80.
A03-12x
Description: Error on System bus. Action: Use "MAP 1230: Linux Platform Error Problem
Resolution" on page 80.
A03-13x
Description: I/O Expansion bus parity error. Action: Use "MAP 1230: Linux Platform Error
Problem Resolution" on page 80.
A03-14x
Description: I/O Expansion bus time-out error. Action: Use "MAP 1230: Linux Platform Error
Problem Resolution" on page 80.
A03-15x
Description: I/O Expansion bus connection failure. Action: Use "MAP 1230: Linux Platform
Error Problem Resolution" on page 80.
A03-16x
Description: I/O Expansion unit not in an operating state. Action: Use "MAP 1230: Linux
Platform Error Problem Resolution" on page 80.
A05-00x
Description: Error log analysis indicates an environmental and power warning, but the failure
could not be isolated. Action: Use "MAP 1230: Linux Platform Error Problem Resolution" on
page 80.
A05-01x
Description: Sensor indicates a fan has failed. Action: Use "MAP 1230: Linux Platform Error
Problem Resolution" on page 80.
A05-02x
Description: System shutdown due to a fan failure. Action: Use "MAP 1230: Linux Platform
Error Problem Resolution" on page 80.
A05-03x
Description: Sensor indicates a voltage outside normal range. Action: Use "MAP 1520:
Power" on page 105.
A05-04x
Description: System shutdown due to voltage outside normal range. Action: Use "MAP 1520:
Power" on page 105.
A05-05x
Description: Sensor indicates an abnormally high internal temperature. Action: Verify that:
1. The room ambient temperature is within the system operating environment.
2. There is unrestricted air flow around the system.
3. All system covers are closed.
4. There are no fan failures.
If none of these problems exist, then proceed with "MAP 1230: Linux Platform Error Problem
Resolution" on page 80.