Dimensions
Height
Width
Depth
Weight
Minimum configuration
Maximum configuration
Electrical
Power source loading (maximum in
kVA)
Power source loading (typical in kVA)
Voltage range (V ac)
Frequency (hertz)
Thermal output (maximum)
Thermal output (typical)
Power Requirements (minimum load)
Power Requirements (maximum load)
Power factor - U.S., World Trade,
Japan
Inrush current¹
Maximum Altitude², ³
Temperature Requirements
Humidity Requirements
(Noncondensing)
Wet Bulb
Model 6E4 Noise Emissions⁴
L
WAd
<L
>
pA
m
Model 6C4 Noise Emissions⁴
L
WAd
<L
>
pA
m
46
Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide
Rack (Model 6C4)
176 mm 6.9 in.
4 EIA Units
448 mm 17.5 in.
816 mm 32.13 in. - Includes 145 mm
for cable management arm
32.0 kg 70.4 lbs.
47.3 kg 104.0 lbs.
100-127 Vac or 200-240 Vac (single phase)
75/amps (maximum at <10ms)
25/amps (maximum at 10ms - 150ms)
Note: The above amps are held for the full input range of 180 V/ac to 259
Operating
5 to 35°C
(41 to 95°F)
Operating
8 to 80%
27°C (80°F)
Operating
6.0 bels
42 dBA
Operating
6.1 bels
44 dBA
Tower (Model 6E4)
544.0 mm (21.42 in.)
308.0 mm (12.13 in.) 191 mm without
789.0 mm (31 in.) - Includes 70 mm
for rear acoustic cover
36.0 kg 79.2 lbs.
51.0 kg 112.2 lbs.
1.20
0.75
50 / 60
2540 Btu/hr
Btu/hr
350 watts
670 watts
0.95
V/ac and 47 to 63 Hz.
2135 m (7000 ft.)
1 to 60°C
(34 to 140°F)
27°C (80°F)
legs
Storage
Storage
5 to 80%
Idle
5.9 bels
41 dBA
Idle
6.0 bels
43 dBA