SPCN Informational Codes

The following values of word 13 indicate an SPCN informational message: C006, C007, C00C, C030,
C0E0, C0E2, C0F0. No action is required by the customer or service representative.
VPD Informational Codes
The following values of word 13 indicate a VPD informational message: E104, E10D, E112, E113, E114.
No action is required by the customer or service representative.

HMC/Partition Surveillance Error Codes

These error codes indicate a problem in the surveillance between the HMC and a partition running on the
managed system.
If you replace FRUs and the problem is corrected, go to "MAP 0410: Repair Checkout" in the RS/6000
Eserver pSeries Diagnostic Information for Multiple Bus Systems.
Error Code
Description
B301 0001 HMC/partition surveillance fault
B301 0002 HMC/partition surveillance fault
B301 0012 HMC/partition surveillance fault
B301 0013 HMC/partition surveillance fault
B301 0019 HMC/partition surveillance fault
B301 0020 HMC/partition surveillance fault
B301 0023 HMC/partition surveillance fault
B301 0025 HMC/partition surveillance fault
B301 0026 HMC/partition surveillance fault
B301 0027 HMC/partition surveillance fault
B301 0029 HMC/partition surveillance fault
B301 002B HMC/partition surveillance fault
B301 002C HMC/partition surveillance fault
B301 002D HMC/partition surveillance fault
Action/
Possible Failing FRU
Contact your service representative
Verify the network between the HMC and the
partition by pinging in both directions. If
problems are found, correct them. Reboot the
HMC.
Contact your service representative if hte
problem persists.
Contact your service representative if hte
problem persists.
Contact your service representative if hte
problem persists.
Contact your service representative
Contact your service representative
Contact your service representative
Contact your service representative
1. If short hostnames are being used for the
HMC and the partitions, insure that the short
hostnames are set up correctly according to
the instructions in "Using Network Adapters
to Communicate With Partitions" in the IBM
Hardware Management Console for pSeries
Installation and Operations Guide, order
number SA38-0590. Correct any problems
that are found (if any), then verify that you
can ping in both directions between the HMC
and partitions.
2.
If short hostnames are not being used, or
the procedure above does not correct the
problem, contact your service rep.
Contact your service representative
Contact your service representative
Contact your service representative
Contact your service representative
Chapter 5. Error Code to FRU Index