Actions: This is an informational message. No action is required by the customer or service
representative.
2526: Informational message.
Actions: This is an informational message. No action is required by the customer or service
representative.
35EF: The scan dump code was not able to successfully complete the request to close the connection to
the load source.
Actions: This is an informational message. No action is required by the customer or service
representative.
9900: Memory allocation failure during firmware update.
Actions:
1. Reset the system using the pin-hole reset button on the operator panel. Retry the operation
that caused this error code.
2. Check for a later level of firmware than the one that you were trying to install. Apply if
available.
3. Call service support.
9901: State sequence error found during CRC query during firmware update.
Actions:
1. Reset the system using the pin-hole reset button on the operator panel. Retry the operation
that caused this error code.
2. Check for a later level of firmware than the one that you were trying to install. Apply if
available.
3. Call service support.
9902: Mailbox LID data failure during firmware update.
Actions:
1. Reset the system using the pin-hole reset button on the operator panel. Retry the operation
that caused this error code.
2. Check for a later level of firmware than the one that you were trying to install. Apply if
available.
3. Call service support.
9903: State sequence error found after a firmware update LID was received during firmware update.
Actions:
1. Reset the system using the pin-hole reset button on the operator panel. Retry the operation
that caused this error code.
2. Check for a later level of firmware than the one that you were trying to install. Apply if
available.
3. Call service support.
9904: Error while flashing an update LID during firmware update.
Actions:
1. Reset the system using the pin-hole reset button on the operator panel. Retry the operation
that caused this error code.
2. Check for a later level of firmware than the one that you were trying to install. Apply if
available.
3. Call service support.
9905: CRC mismatch after a firmware update LID was received during firmware update.