Table 4. Firmware Error Codes. (continued)
Error Code Description
20E0 0009 Invalid password entered - system locked
20EE 0003 IP parameter requires 3 dots "."
20EE 0004 Invalid IP parameter
20EE 0005 Invalid IP parameter (>255)
20EE 0007 Keyboard not found
20EE 0008 No configurable adapters were found in the
system by the remote IPL menu in the SMS
utilities.
20EE 0009 Unable to communicate with the service
processor.
20EE 000A The image size on the boot or installation
device exceeds the system firmware memory
limitations.
20EE 000B The system was not able to find an operating
system boot record on the devices listed in the
boot list.
This can be caused by the wrong devices being
in the boot list, a problem that prevents the
system from communicating with the device
that contains the boot record, or the boot record
being corrupted.
232
Eserver pSeries 630 Model 6C4 and Model 6E4 Service Guide
Action/
Possible Failing FRU
The password has been entered incorrectly 3
times.
Turn off, then turn on the system unit, then
enter the password correctly.
Enter valid IP parameter.
Example: 000.000.000.000
Enter valid IP parameter.
Example: 000.000.000.000
Enter valid IP parameter.
Example: 255.192.002.000
1. Plug in keyboard.
2. Replace the CEC backplane.
Location: U0.1-P1
This warning occurs when the remote IPL menu
in the SMS utilities cannot locate any LAN
adapters that are supported by the remote IPL
function. If a supported device is installed:
1. Replace the adapter.
2. Go to "MAP 1542: I/O Problem Isolation" on
page 127.
Replace the CEC backplane
Location: U0.1-P1.
1. Check for system firmware updates. Apply if
available.
2. Call service support.
Go to "Boot Problems/Concerns" on page 204.