IBM pSeries 630 6C4 Service Manual page 239

Hide thumbs Also See for pSeries 630 6C4:
Table of Contents

Advertisement

Table 2. SPCN Error Codes for the CEC (system unit) (continued)
Error Code Description
1011 2600 Pgood fault
1011 2603 Pgood fault
1011 2612 Optical converter fault
1011 3100 I2C controller fault
1011 3104 VPD collection problem with SES devices
1011 3105 I2C port 5 fault
1011 3114 PCI riser card fault
2
1011 3116 I
C VPD interface
1011 3118 SPCN VPD and NVS interface
1011 3119 VPD collection problem with DASD backplane
1011 311E VPD collection problem with PCI riser
1011 7610 System processor fan 1 failure
1011 7611 Processor card cooling fan missing from primary
location
1011 7620 System processor fan 2 failure
1011 7621 System processor fan 2 missing
Action/
Possible Failing FRU
CEC backplane
Location: U0.1-P1
CEC backplane
Location: U0.1-P1
CEC backplane
Location: U0.1-P1
CEC backplane
Location: U0.1-P1
1. DASD backplane
Location: U0.1-P3
2. PCI riser
Location: U0.1-P2.
3. System backplane
Location: U0.1-P1
CEC backplane
Location: U0.1-P1
1. PCI riser card
Location: U0.1-P2
2. CEC backplane
Location: U0.1-P1
CEC backplane
Location: U0.1-P1
CEC backplane
Location: U0.1-P1
DASD backplane
Location: U0.1-P3
PCI riser card
Location: U0.1-P2
1. Processor fan 1
Location: U0.1-F1
2. CEC backplane
Location: U0.1-P1
1. Processor fan 1
Location: U0.1-F1
2. CEC backplane
Location: U0.1-P1
1. Processor fan 2
Location: U0.1-F2
2. CEC backplane
Location: U0.1-P1
1. Processor fan 2
Location: U0.1-F2
2. CEC backplane
Location: U0.1-P1
Chapter 5. Error Code to FRU Index
219

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pseries 630 6e4

Table of Contents