Table of Contents
Introduction
15
Introduction
3
Warning and Precautions
4
Working Conditions
5
Graphics and Symbols
8
Labels
9
Intended Use
11
ABX Micros
13
Table of Contents
15
Technical Specifications (V1.7.0)
19
Technical Specifications (V1.7)
19
Parameters
19
Throughput Analysis
20
Calibration
21
Measurements and Computation
21
Memory Capacity (Smart Cards)
21
Outputs
21
Reagents
21
Statistics and Quality Control
21
Physical Specifications
22
Barcode Reader Options
22
Dimensions and Weight
22
Display
22
Minimum Sample Volume
22
Operating Temperature/Humidity
22
Power Requirements
22
Wastes
22
Counting Aperture Diameter
23
Dilution Ratios
23
Hemoglobin Measurement
23
Summary of Performance Data
24
Precision (Reproducibility)
24
Precision Claims
25
Linearity
26
Precision (Repeatability)
26
Carry-Over
27
Normal Ranges
27
Accuracy
28
Leucocytes Differential Count
28
Sample Stability Study
28
Limitations
29
Blood Specimens
29
Maintenance
29
Sample Collection and Mixing
29
Sample Stability
29
Anti-Coagulants and Their Effects (on Whole Blood)
30
HCT (Hematocrit)
30
Known Interfering Substances
30
RBC Red Blood Cells (Erythrocytes)
30
WBC White Blood Cells (Leukocytes)
31
HGB (Hemoglobin)
32
MCH (Mean Corpuscular Hemoglobin)
32
MCHC (Mean Corpuscular Hemoglobin Concentration)
32
MCV (Mean Corpuscular Volume)
32
RDW (Red Cell Distribution Width)
32
MPV (Mean Platelet Volume)
33
PLT (Platelets)
33
GRA # (Granulocyte Count Absolute Number)
34
GRA % (Granulocyte Percentage )
34
LYM # (Lymphocyte Count Absolute Number)
34
LYM % (Lymphocyte Percentage)
34
MON # (Monocyte Count Absolute Number )
34
MON % (Monocyte Percentage)
34
Reagent Specifications
35
Reagent Consumption
36
Waste Handling Procedure
36
Description & Technology
37
Section 2. Description & Technology
37
1 Description
38
Overview
38
Front View (Covers Opened)
38
Left Side View (Covers Opened)
39
2 Technology
39
Sampling
39
Dilutions
40
Rbc/Plt
40
Wbc/Hgb
40
CBC Measurement Principles
41
Rbc/Plt
41
Hgb
43
Hct
44
MCV, Mch & Mchc
44
Mpv
44
Pct
44
Rdw
44
Pdw
45
Wbc
45
Workflow
47
Section 3. Workflow
47
1 Startup Checks
48
Reagent Level Checks
48
Bottled Units
48
Minipack Units
48
Printer Power and On-Line Checks
48
Instrument Startup
49
Blood Sample Collection
49
2 Daily Quality Control & Calibration Verification
50
3 Sample Selection and Identification
51
Sample Identification Modes
51
Standard Mode
51
US Mode
51
4 Running Samples
53
Preliminaries
53
US Mode
53
Standard Mode
53
Automatic Cleaning Cycle
53
End of the Day Rinsing
54
5 Results
55
ABX Micros 60 CS/CT8
55
Displayed Results
55
Flags
55
Identification
55
Results Printout
56
ABX Micros 60 CS/CT16
58
Displayed Results
58
Flags
58
Identification
58
Result Printout (US Mode Example)
59
6 Flags
60
ABX Micros
60
Normal Limits
60
Flags Causing Analysis Reject
60
Results Exceeding Linear Range
60
HGB Blank Reference
61
Results Comparable
61
Results Rejected
61
Morphology Flags
62
Flags on PLT Distribution Curve
62
Flags on WBC Distribution Curve
62
Quality Assurance
65
Section 4. Quality Assurance
65
1 Quality Control
66
Functions
66
Automatic (with Q.C. Smart Card)
66
QC Smart Card Messages
67
Select Commercial Control Level
67
Select Operator
67
Running Control Blood
68
Accepting or Rejecting QC Results
69
QC Results
69
Analysis (Without Q.C. Smart Card)
71
Print Targets (Only with Q.C. Smart Card)
71
Statistics (Only with Q.C. Smart Card)
72
Graphs (Only with Q.C. Smart Card)
73
2 Calibration
75
General Recommendations
75
Calibration Procedure
75
Preliminaries
75
Calibration Function
75
Change Expiration Date
76
Change Lot Number
76
Change Number of Calibration Samples
76
Changing the Target Value
76
Calibration Results
77
Running Calibrator
77
Verify Calibration
78
Calibration Passed
79
Calibration Failed
80
RDW Calibration
81
RDW Calibration Using a Quality Control Standard
81
Calibration Coefficients
82
Changing Calibration Coefficients
82
Calibration Coefficient Limits
83
Setup
85
Section 5. Setup
85
1 Setup Overview
86
2 Results Options
87
Reprint Results
87
Units
88
Printer Selection
89
Temperature Printout
89
Print Limits
90
Print LMG Results
90
3 Laboratory Limits
91
Results Low Limits
91
Results High Limits
91
Print Limits
92
Morphology Flag Limits
93
Platelet Flags
93
WBC Flags
93
4 Special Functions
94
Changing Operator
94
Changing (the User) Password
94
Choosing Startup Cycle
95
Setting Autocleaning Frequency
95
Printing Instrument Configuration
96
5 Date and Time
98
Setting Buzzer Cycle End
98
Choosing Sample Identification Mode
98
6 Host Computer Options
99
Change Time
99
Change the Date Format
99
Change Date
99
Host Communications
100
Baud Rate
100
Transmission
100
7 Barcode Setup
101
8 Memory Card
101
Memo on / off
101
Running Patient Samples
102
Transmission of Results
102
Print List
102
Reprint One Result
103
Reprint All Results (TR. ALL)
104
Reprint from / to (TR. from TO)
104
Clear Card (Erasing All Results from the Card)
105
Maintenance & Troubleshooting
107
Section 6. Maintenance & Troubleshooting
107
1 Maintenance
108
Daily Maintenance
108
Automatic Cleaning
108
Startup and Standby Cycles
108
General Cleaning of the Instrument
109
Reagent Connections
110
Alphalyse 360
110
Bottle Connections
110
Reagent Pack Connection
111
Diluent & Waste Connection
113
Reagent Priming
113
Service Functions
114
Cover Dismantling
114
Menu Service Overview
114
Backflush
115
Troubleshooting
116
Drain Chambers
116
Prime Reagents
116
Concentrated Cleaning
117
Mechanical Checks
117
Instrument Cycles
119
Technician Functions
119
Automatic Cleaning
119
Manual Probe Cleaning
119
Unblocking the Sample Probe
120
Replacing the Sample Probe
121
Extended Concentrated Cleaning
122
2 Troubleshooting
123
Overview
124
Problem Identification
124
Reagents
124
System Operations
124
Calibration
125
Precision
125
Troubleshooting Parameters
125
Problems on All Parameters
126
Problems on RBC/PLT Parameters Only
127
Problems on WBC/HGB Parameters Only
128
Troubleshooting System Operations
129
Troubleshooting Specific ERROR Messages
130
3 Menu/Overview