4.2.SIGNAL SENDING TEST

Image information signals, control signals and DTMF can be individually output. Additionally, signal sounds can
be monitored by monitor speaker.
<Operational Procedure>
(1)
Press [Signal Sending Test].
(2)
Select a test item.
(3)
Select the parameter you would like to test by pressing [+] or [-] key.
(4)
Press the [Start] key.
Note: In order to move to another test, select the next test item after pressing the [Stop] key.
Contents of Test
V34 Main CH
V34 Control CH
V8
V17t
V29
V27ter
V21
PB
DP
Special Tone
Optional Tone
PB Tone (High)
PB Tone (Low)
Pseudo Ring
Parameter
33600 / 31200 / 28800 / 26400 /
24000 / 21600 / 19200 / 16800 /
14400 / 12000 / 9600 / 7200 /
4800 / 2400 [bps]
CTL CH / INFOc / INFOa /
ToneB / ToneA
CM / JM
14400 / 12000 / 9600 /
7200 [bps]
9600 / 7200 [bps]
4800 / 2400 [bps]
-
0 / 1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9 /
* / # / A / B / C / D
0 / 1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9
1100 / 1300 / 1650 / 2100
200 to 4000 [Hz] (In steps of 100Hz)
1209 / 1336 / 1477 / 1633 [Hz]
697 / 770 / 852 / 941 [Hz]
-
SIGNAL SENDING TEST
Factory-shipped
Default Setting
33600 [bps]
CTL CH
CM
14400 [bps]
9600 [bps]
4800 [bps]
-
0
0
1650
200 [Hz]
1477 [Hz]
697 [Hz]
-