18. Malfunction code
18.3.35
C002: RAM error at startup (standard memory)
C003: RAM error at startup (expanded memory)
MFP board/2 (MFPB/2)
Step
1
Reboot the main body.
Check connection state of the standard/
2
expanded memory and correct as neces-
sary.
Check the MFPB/1 connector for proper
3
connection and correct as necessary.
4
Change the standard/expanded memory.
5
Change MFPB/2.
18.3.36
C013: MAC address error at startup
C015: BOOT ROM error at startup
C022: NVRAM error at startup
MFP board/2 (MFPB/2)
Step
1
Reboot the main body.
Check the MFPB/1 connector for proper
2
connection and correct as necessary.
3
Change MFPB/2.
346
Relevant electrical parts
Action
Relevant electrical parts
Action
Field Service Ver. 1.0 Sep. 2008
Standard memory
Expanded memory
WIRING DIAGRAM
Control signal
⎯
⎯
⎯
⎯
⎯
WIRING DIAGRAM
Control signal
⎯
⎯
⎯
Location (electri-
cal component)
⎯
⎯
⎯
⎯
⎯
Location (electri-
cal component)
⎯
⎯
⎯