Test (only available on alarm panel)

Select the corresponding function.
An overview of the different functions and
Function
Walk Test
Keypad
Sirens & Sounders
Meaning
Chime
• On
An info tone sounds when a detector is operated.
• Off
No info tone sounds.
System
All detectors belonging to the system can be tested here. Activate all detectors in the
building one after the other. If a detector is triggered the alarm panel emits two signal tones
It also indicates on the display whether a tamper contact (S) and/or alarm (A) was triggered.
The top of the display shows the number of zones still to be tested (alarm and tamper).
When all detectors have been tested the system writes "All Zones tested".
Partitions
• Detectors from a specific partition can be tested here.
• Once the partitions are selected only the detectors in the selected partitions are displayed.
Zones
• Selected detectors can be tested here.
• A list of all detectors appears. Select the detectors to be tested with Yes.
Press all buttons on the keypad one after the other.
The corresponding character or button function is shown on the display in response.
Press the dual keys (fire alarm, hold up alarm, medical emergency or social care alarm) at
the same time to test them.
The function of the key combination is shown on the display in response.
Int.Sirens
• The sounders on the alarm panel, info module, indoor siren and wireless control device
are actuated.
Ext. Radio Sirens
• The sounders for the wireless external sirens are actuated.
Sounder Module
• The sounders for the external sirens are actuated. External siren in connection with the
wireless accessory module (WAM) as a "Sounder Module".
Loudspeakers
• Select "Play/Stop" to hear all existing messages in the system one after the other.
their features can be found in the following table.