Configuration
Function
Control Devices
Door Locks
146
Meaning
Press the function buttons on the wireless control device one after the other.
Wait 2 to 3 seconds between each button so that the control device can send each message.
A corresponding letter appears on the display in response:
A = "arm" button (closed lock)
C = "internal arm" button (*)
D= "query status" button (?)
B = "disarm" button (open lock)
To test the number buttons, press 4 or 6 numerical buttons (corresponding to the set
code length) and then a function button: Example:
• Press
: 1234?
• Displayed
: 1234D
Press the dual keys (fire alarm, hold up alarm, medical emergency or social care alarm) at
the same time to test them. On the display:
F = dual keys fire alarm
P = dual keys hold up
M = dual keys medical emergency
H = dual keys social care alarm
The lower "*" and "#" button on the control device cannot be tested.
Select the door lock to be tested.
Operate the corresponding door lock.
After unlocking, "Unlocked" appears on the display.
After locking, "Locked" appears on the display.
• Secvest key: press the button and then lock.
• Additional door lock: do not press the button. Then lock.
Note
You can check here whether DIP switch 3 in the Secvest key is correctly
set according to the door stop.
The received signal strength is also displayed.
The meaning of the number before and inside the brackets can be found
in the signal strength explanation on the following page.