Configuration
Selecting a partition
Note
The taught-in detectors are assigned to
Partition 01 by default.
To assign the detector to another partition,
proceed as follows:
1.
Use the checkboxes to select the desired
partition(s) in which this zone will be monitored.
Note
At least one partition must be selected.
Setting options for the partitions can be found in section
"Configuring Secvest via web server -> Partitions" in this
manual.
Zones of the following types can be assigned to one
or more partitions: Normal Alarm, Zone Lock, Final
Door, Entry Route, Key Switch, Key Box, Log Only,
Exit Terminate, Lock Set and Exit Norm Alm.
Note
If you plan on using internally armed partitions,
you must ensure that the internally armed options
are the same for all zones used for more than one
partition.
The wireless alarm panel does not allow zones of
the following types to be assigned to more than
one partition: 24 Hour Alarm, Fire Alarm, Hold Up
Alarm, Perimeter Warning, Tamper and Technical
Alarm.
Selecting zone attributes
1.
Use the checkboxes to select the desired attribute(s).
Attribute
Explanation
Chime
Each time this zone is triggered when
the alarm panel is disarmed, the panel
sounds an acoustic signal.
Force Set
If a zone is given this attribute, this zone
Omit
is automatically omitted if it was open
when the system was armed.
44
Attribute
Explanation
Omittable
If a zone is given this attribute, a user can
omit this zone before arming the system.
If a user attempts to arm the system
when a zone with this attribute is open,
a warning appears and the arming
process is interrupted.
The user can acknowledge this warning
and continue the arming process.
Dis.
This attribute is an additional attribute for
Sabotage
mechatronic ABUS door and window locks.
The "Normal Alarm" zone type must be
selected.
When the "Dis. Sabotage" attribute is
selected, pry-attempt monitoring of the
supported mechatronic products is
switched off when the alarm system is
disarmed. This attribute is not
recommended and is only necessary is
special cases.
A "W" appears in the attribute line on the
alarm panel display.
Soak Test
If a detector tends to trigger a false alarm,
activate the soak test.
This setting resets automatically after
14 days.
The detector does not trigger any
alarms on the alarm panel during this
time.
However, all triggers are written to the
memory (log book) for analysis purposes.
Part
This zone is monitored when the partition
Set
of this zone or all partitions are internally
armed.
Activity
The function of the detector is reversed
Monitor
(inverted). This should only be used in
connection with the social care
emergency call.
An alarm is triggered on the alarm panel
when the detector does not register any
alarm within a certain time period.