Abus SECVEST Installer Manual page 65

Hide thumbs Also See for SECVEST:
Table of Contents

Advertisement

Type
Full Set
Setting Complete
Armed
Rearmed
Part Set Ready
Part Setting Complete
Part Set
Set Fault
Autoset Warning
Explanation
This output is only activated when all of the partitions
configured in the system are armed.
This output is activated (for approx. 10 seconds) when
the system or partition is armed or internally armed.
This output is activated when the partition is armed.
The output is activated for approx. 10 seconds.
The output is activated in an internally armed system
when the system is rearmed at least once.
If the confirmation mode has been set to DD243 or
BS8243, the alarm panel activates the output as soon as
the system is rearmed (after the confirmation timer).
If the confirmation mode "Basic" is selected, the alarm
panel activates the output as soon as the system is
rearmed (after the siren time has expired).
In a system with partitions, the output can be assigned to
different partitions.
The output is deactivated again when a user or installer
resets the system or the partition.
This output is activated when the partition is ready to be
internally armed.
If a detector is assigned to more than one partition,
the partition in question is ready even if this detector is
still open.
This output is activated (for approx. 10 seconds) when
the system or partition is INTERNALLY armed.
This output is activated when a partition is internally
armed.
This output is activated when arming fails. It remains
activated until the user confirms the fault.
This output is activated when the warning time for
automatic arming is running. (See menu "Schedulers
Set/Unset".)
This output is deactivated when the system is armed or
a user delays or cancels automatic arming.
Configuration
Can be assigned
to partitions
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
65