Configuration
5.
Select WAM Info.
6.
Select WAM 1.
Note
When the wireless accessory module is taught in,
its configuration is also transferred, so it is
possible to see under "WAM Info" which function
the wireless accessory module had when it was
taught in.
Function
Explanation
Not
The wireless accessory module is not
Used
taught in.
1 Wireless
Received wireless signals from
Repeater
taught-in wireless detectors (taught
into the WAM) are forwarded to the
alarm panel. No further settings are
necessary here.
2 Output Module
Up to four relays of the WAM can be
activated by the wireless alarm panel
according to the configuration.
3 T/R Module
Zone and output module for connection
of wired detectors (flood detectors) or a
block lock/key switch.
4 Sounder Module For connection of a wired external
sounder or compact alert.
WAM as wireless repeater (WAM function 1)
If the wireless accessory module is taught in with the
wireless repeater function, the wireless detectors with
signals that this module should transmit should also be
taught into the WAM.
See the instructions for the wireless accessory module
(WAM) for this.
WAM as output module (WAM function 2)
Note
If the wireless accessory module is taught in with
the output function, the alarm panel automatically
reserves the corresponding outputs in the panel
for this module.
56
Note
These outputs no longer have to be added manually.
Simply define the settings for the output function
as described in section Editing outputs.
These outputs only need to be configured but no
longer have to be added.
See the instructions for the wireless accessory
module (WAM) for this.
WAM as zone and output module (WAM function 3)
Note
If the wireless accessory module is taught in with
function 3, the alarm panel automatically reserves
the corresponding zone and outputs in the panel
for this module.
Input 1 and input 2 form the wired zone of the WAM.
Input 1 functions as the connection for the alarm loop.
Input 2 functions as the connection for the tamper zone.
Both of these connections correspond to the
associated wireless zone.
During wiring see the instructions for the wireless
accessory module (WAM) for this.
WAM as sounder module (WAM function 4)
If the WAM is configured as a sounder module, a display
appears upon connection, where you have to configure
the partitions for which the sounder will be activated.
This setting is defined similarly to the setting for the
external sirens.
The connection of the compact alert in the WAM can
be found in the instructions for the wireless accessory
module (WAM).
Note
Ensure that the voltage-free outputs on the WAM
can be loaded with max. 500 mA at 24 volts.
These outputs are optocouplers with a forward
resistance of 2 Ω.
Delete All (alarm panel only)
1.
Select Delete All.
2.
Confirm the selection with Next.
3.
Confirm the security prompt with Yes to delete the
WAM or Back if you are not sure.