Name/function
RF Jamming
Tamper Omit
Explanation (checkbox)
Dropdown selection field for alarm system response for jamming:
The alarm panel can detect jamming of wireless signals.
Corresponding processes are activated as follows:
Alarm panel is armed
Disabled
No response
• Log book entry of this event
Fault
• No display and no warning
tones
• Tamper alarm
Tamper
• Jamming is reported
Note:
If "Tamp as Tamp-Only" is
disabled, the "Jamming" or
"Fault" outputs are also activated.
If no tamper channel is assigned
in FF, an "unconfirmed alarm"
is sent.
Note
The "Tamper" option is required in order to comply with PD 6662:2010.
If the "Tamper" option is used along with the following setting:
System -> User Reset -> System Tampers = No
the user cannot reset the system.
If a user omits a zone it may be necessary to also omit the associated tamper
circuit for this zone.
Activated
The tamper contact is also omitted within an omitted zone.
Deactivated
The tamper contact continues to be monitored within an omitted zone.
Configuration
Alarm panel is disarmed
No response
• Log book entry of this event
• Display and warning tones
• Tamper alarm
• Jamming is reported
Note
If "Tamp as Tamp-Only" is
disabled, the "Jamming" or
"Fault" outputs are also activated.
If no tamper channel is assigned
in FF, an "unconfirmed alarm"
is sent.