Configuration
Name/function
Siren time ext. [min]
Strobe on Set
Strobe on Unset
74
Explanation
Time for the duration of the external siren(s) in minutes.
The siren time can be set to a value between 0 and 15 min.
If sounders are assigned to multiple partitions, the alarm panel uses the longest
siren time set for the partitions in question.
On
After successfully arming the partition, there is one visual acknowledgement on
the wireless external siren.
"Strobe" outputs are activated for 10 s after successfully arming the partition.
Off
After successfully arming the partition, there is no visual acknowledgement on the
wireless external siren.
On
After successfully disarming the partition, there is one visual acknowledgement on
the wireless external siren.
"Strobe" outputs are activated for 10 s after successfully arming the partition.
Off
After successfully disarming the partition, there is no visual acknowledgement on
the wireless external siren.