Type
Explanation
Tamper Return
This zone is used to monitor the fault output of external sounders. Monitoring of this zone is
permanently enabled. If a zone with this type is triggered when the wireless alarm panel is
disarmed, only the internal siren is activated. If this alarm is triggered when the system is armed,
the communication can be sent if configured accordingly and external sounders with strobe can be
triggered. This zone type can have the following attributes: "Soak Test", "Part Set", "Omittable" and
"Force Set". This zone type is not available for wireless zones.
Ext PSU A/C
This zone is used to monitor the AC fault output of an external power supply. If a zone of this type
fault
is triggered, the wireless alarm panel reacts as if there were a "Panel A/C fault" on the panel itself.
The response depends on the configuration. This zone type is not available for wireless zones.
Ext PSU Batt
This zone is used to monitor the battery fault output of an external power supply. If this fault is
Fault
triggered, outputs configured for "Battery Fault" are activated and "Ext PSU Batt Fault" appears on
the display. If this fault is triggered while the system is armed, a log book entry is created and the
communication configured accordingly is started, but no alarm is triggered until the wireless alarm
panel is disarmed. This zone type is not available for wireless zones.
Ext PSU Low
This zone is used to monitor a fault output for "low battery" of an external power supply. If this fault
Volts
is triggered, outputs configured for "Low Volts" are activated and "Ext PSU Low Volts" appears on
the display. If this fault is triggered while the system is armed, a log book entry is created and the
communication configured accordingly is started, but no alarm is triggered until the wireless alarm
panel is disarmed. This zone type is not available for wireless zones.
Ext PSU Fault
This zone is used to monitor the fault output of an external power supply. If this fault is triggered,
outputs configured for "Ext PSU Fault" are activated and "Ext PSU Fault" appears on the display.
If this fault is triggered while the system is armed, a log book entry is created and the
communication configured accordingly is started, but no alarm is triggered until the wireless alarm
panel is disarmed. This zone type is not available for wireless zones.