Configuration
Type
Ext PSU Fault
Ext PSU Low Volts
General Fault
Fault comm. path
Full Set Ready
Full Setting Complete
64
Explanation
The output is activated when an external power supply
detects a fault and reports the fault using zone type "Ext
PSU Fault".
The output is only deactivated when the fault is corrected
and the user confirms the alarm with a valid code on the
alarm panel.
The output is activated when an external power supply
detects a correspondingly low voltage using zone type
"Ext PSU Low Volts".
The alarm panel deactivates the output as soon as
the zone is reset and the user confirms the fault with a
valid code.
The output is activated as soon as an event occurs that
causes a fault.
This includes:
• RF Low Battery
• RF Supervision
• RF Jamming
• A/C Fault
• Battery Fault
• Ext PSU Fault
• Tamper
Note that in the event of an A/C Fault the output is already
activated a few seconds after the fault is detected and is
NOT influenced by the set delay time.
The output is activated as soon as the alarm panel
identifies a fault in the communication method and is
deactivated when the fault no longer exists.
This output is activated when the partition is ready to
be armed.
If a detector is assigned to more than one partition,
the partition in question is ready even if this detector is
still open.
The output is activated as soon as the system is
successfully armed. The output is activated for approx.
10 seconds.
Can be assigned
to partitions
No
No
Yes
No
Yes
Yes