Configuration
Name/function
Remote Inst. Set
Duress Enable
94
Explanation (checkbox)
Use this option to decide whether the alarm panel is armed or internally
armed after the remote control is operated.
Activated
The possible partitions are armed or internally armed immediately.
If an exit delay is configured, this is overridden and the alarm system is armed
immediately as soon as the "arm" button on the remote control is pressed.
Deactivated
The possible partitions are armed or internally armed according to the set
exit mode.
Activated
The administrator has the option of creating a "Duress Code User".
The system can be armed or disarmed using a duress code.
Important
If a user is forced by an intruder to disarm the alarm system, they should disarm
the system using a duress code.
The alarm panel then responds as follows:
• The configured communication for duress is started.
• No sounders are activated.
• The alarm panel siren is not activated, and no triangle warning appears on
the display.
The alarm panel can also be rearmed or internally armed again using the
HUA code.
This is useful if the intruder forces you to rearm the alarm panel.
In this case the intruder is checking whether the code you entered is a
"normal" code.
"Duress" outputs are activated.
Corresponding log book entries are generated.
Deactivated
There is no option to create a "Duress Code User".