Configuration
Name/function
Auto Rearm
Silence Alerts
(silent warnings)
Abort time
106
Explanation (checkbox)
Appears when the following is set:
System->Confirmation->Confirmation Mode->Basic
Select how often the system automatically rearms after the siren time has expired.
Dropdown selection field for:
• Never
• The alarm panel never rearms. The alarm panel switches to the alarm status
just one time.
• 1 x, 2 x, 3 x, 4 x, 5 x
• Always
he system rearms all closed zones but not the detectors still sending
T
alarm signals.
• One of these settings is required in order to comply with EN 50131.
• If the system is rearmed, an acoustic internal alarm instead of the normal
entry tone is generated by the wireless alarm panel if a user enters through
the entry route.
This option controls the length of time in which warning tones (a brief "beep" every
few minutes) are sounded.
Dropdown selection field for:
• User Code
• Warnings are sounded until a user enters their code to confirm the warning.
• 30 minutes
• 60 minutes
• 120 minutes
• Warnings are sounded for the set amount of time. The warning tones can be
stopped by entering a user code.
• No alert tones
• No acoustic alerts are sounded.
Note
The alarm panel does not display any warnings as long as a partition is still armed.
Input field for the alarm abort time in seconds (value between 0 and 120).
The alarm panel always starts this time when an alarm has been triggered. If a user
mutes the alarm during this time, no installer reset is required.
If an alarm occurs and a user disarms the system within this time, "Alarm Abort"
outputs are activated and an alarm abort is reported.