Name/function
Quick Set
Quick Omit
User Code Req'd
2 Way Replies
Explanation (checkbox)
Activated
Alarm system can be armed using the symbol keys without entering the user
code first.
Deactivated
Alarm system can only be armed after the user code has been entered.
Activated
Open zones are automatically omitted when the alarm system is armed (if the zone
attributes for omission allow).
Deactivated
Open zones must be manually omitted when the alarm system is armed.
Use this option to ensure that an installer only has access to the system when a
user is present.
Activated
After the installer has entered their code, the system prompts the user to enter
their user code. Only once a user code has also been entered does the installer
gain access to the system.
Deactivated
The installer can access installer mode after entering their code; no additional user
code is required.
Note
This setting is not compliant with EN 50131.
This setting only complies with BS8243 when the user has provided written
consent.
Activated
There is active status feedback from the wireless alarm system to the wireless
remote control, wireless control device, Secvest key and additional door lock.
Deactivated
2 Way Replies are deactivated.