Abus SECVEST Installer Manual page 98

Hide thumbs Also See for SECVEST:
Table of Contents

Advertisement

Configuration
Name/function
Entry Keypad Lock
(Confirmation Mode DD243 and
BS8243 only)
Unconfirmed Reset
(Confirmation Mode
DD243 and BS8243 only)
After Entry
(Confirmation Mode
DD243 and BS8243 only)
Confirmed Reset
(Confirmation Mode
DD243 and BS8243 only)
HUA Confirm Time
(Confirmation Mode BS8243 only)
Tamp as Tamp-Only
(Confirmation Mode BS8243 only)
98
Explanation (checkbox)
Activated
The user must disarm the system using an alternative device (not control device or
alarm system), e.g. a remote control or key switch (relevant for DD243 and BS8243).
Deactivated
The user can disarm the system by entering their access code on the keypad
(on control device or alarm system) after the entrance door has been opened
(relevant for DD234).
Dropdown selection field for:
• Installer
• User
Dropdown selection field for:
• Never
• 2 zones (DD243 only)
• 1 zone
Dropdown selection field for:
• Installer
• User
Input field for the confirmation time for hold up alarms in hours.
Note
As per BS8243 confirmation time must be set to between 8 and 20 hours.
Activated
Deactivated

Advertisement

Table of Contents
loading

Table of Contents