Configuration
Type
Not Used
Burglar Alarm
Burg Confirm Alarm
Burg Confirm Timer
Perimeter Warning
Hold Up Alarm
60
Explanation
This output is not used and not activated at any time.
This output is activated when one of the following zone
types or events is triggered and the system is armed:
• Normal Alarm
• Tamper (only when system is armed)
• Entry Route
• Tamper zone (only when system is armed)
• Entry delay expired
• 24 Hour Alarm (only when system is armed)
This type only functions when confirmation mode BS8243
is selected under "System -> Confirmation".
A confirmed burglar alarm has occurred (normal alarm).
The alarm panel activates the output when:
• Two "normal alarms" are triggered in the same partition
during the confirmation time
• A "normal alarm" and a tamper alarm are triggered in
the same partition during the confirmation time.
This output type can be used for one or more partitions.
Note that "normal alarms" and tamper alarms must be
located in the same partition as the output.
The output is deactivated when a user resets the system.
This output is activated while the timer for confirmation of
a burglar alarm is running and is deactivated as soon as
the timer stops.
The output is activated when a perimeter warning is
triggered.
This output is activated when a hold up alarm is triggered. Yes
Can be assigned
to partitions
Yes
Yes
Yes
No
Yes