Hardware

Name/function
Zone type (alarm panel)
RF Siren Options
Battery 2
Explanation (checkbox)
Dropdown selection field for:
Use of inputs for wired zones
• Don't change
• 2-wire FSL 2K2/4K7
• 2-wire FSL 1K/1K
• 2-wire FSL 2K/2K
• 2-wire FSL 4K7/4K7
• 4-wire CC
• 2-wire CC
Dropdown selection field for:
Siren configuration. Select here how the wireless siren responds to fire alarms,
burglar alarms and hold up alarms.
• Siren+Strobe
The wireless siren operates the siren and strobe when an alarm is triggered.
• Strobe
The wireless siren operates only the strobe when an alarm is triggered.
When a second battery is connected, this option enables or disables warning
messages for the second backup battery.
Activated
The alarm panel displays warning messages when battery 2 is missing or has
low voltage.
Deactivated
The alarm panel ignores the presence or absence of the second additional battery.