Name/function
Siren Delay
Siren time ext. [min]
Pt.Set Final Exit
Explanation
Time for the delay duration of the siren(s).
The siren delay can be set to a value between 0 and 10 min.
When an alarm has been triggered the alarm panel waits until this time has expired
before it activates the sirens.
Note
The siren delay only goes into effect when the alarm response includes comms.
The siren delay does not go into effect when a comms fault occurs.
The siren delay does not go into effect when "Installer Mode->System
->Confirmation->Confirmation Mode->DD243 or BS8243" and "Installer Mode-
>System->Confirmation->Siren On ->Unconfirm" are set.
If sounders (or just control devices?) are assigned to multiple partitions, the alarm
panel uses the shortest siren delay set for the partitions in question.
Time for the duration of the external siren(s) in minutes.
The siren time can be set to a value between 0 and 15 min.
If sounders (or just control devices?) are assigned to multiple partitions, the alarm
panel uses the longest siren time set for the partitions in question.
The time that the sounders are active for may also be extended by the longest of
the siren delays that the assigned partitions possess.
This option controls how a "Final Door" zone is handled when the system is
internally armed.
Final Door
• Every zone in this partition with type "Final Door" and the attribute
"Part Set" continues to function as a "Final Door" zone.
Normal Alarm
• Every zone in this partition with type "Final Door" and the attribute
"Part Set" functions as a "Normal Alarm" zone.
Configuration
81