Name/function
Entry Alarm Delay
Broadcast Panel Status
Explanation (checkbox)
Additional delay when deviating from the entry route.
Select whether the user is permitted an additional time of 30 seconds when
deviating from the entry route, before an external alarm is started.
Activated
Additional delay (30 s) activated when deviating from the entry route.
If a user deviates from the entry route within the entry delay time, the alarm panel
waits 30 s before triggering a full alarm. Only an internal alarm is triggered first
within these 30 s.
If a user enters their code within these 30 s, the user can reset the system.
This setting is compliant with EN 50131.
Deactivated
No additional delay when deviating from the entry route.
An alarm is immediately triggered if a user deviates from the entry route and is
caught by another detector in the process.
This setting is not compliant with EN 50131.
Activated
A status change to the alarm system is always transmitted to the wireless
control device. The control device signals the status of the partitions, alarms and
entry and exit delays "just in time".
Deactivated
The status of the alarm panel is only transmitted to the control device when queried
("?" button on the control device). The status of the partitions, alarms and entry and
exit delays are not displayed or signalled on the control device.