Abus SECVEST Installer Manual page 119

Hide thumbs Also See for SECVEST:
Table of Contents

Advertisement

Name/function
21CN Ack Time
Unset Comms
Burg
Comms
Rearm
Dynamic Test Call
Telecoms Priority
Explanation (checkbox)
An analogue telephone connection to the ARC, directed via the new public telephone
networks, sometimes takes more time than a conventional analogue connection to
transmit the information including confirmation with the Fast Format protocol.
Use this option to set the wait time for the confirmation.
Dropdown selection field for:
• 400 ms
• 600 ms
• 800 ms
• 1000 ms
• 1200 ms
Activated
The alarm system transmits all status messages to the ARC, regardless of whether
the system is armed or disarmed.
Deactivated
The alarm system transmits tamper, network failure and other status messages to
the ARC while it is armed. When disarmed, the status messages are not transmitted
to the ARC.
Appears only when the following is set: "System  Confirmation  Confirmation
Mode = Basic" and "Communications  Protocol = Fast Format"
Activated
• The alarm system activates channel 3 again as soon as the siren time has expired.
After channel 3 has been reactivated, an event can be transmitted again if it occurs.
The system automatically omits triggered zones in this case.
• Note: if a "Final Door" zone is triggered, channel 3 is activated at the end of the
configured entry/exit time.
Deactivated
Channel 3 remains activated until a user or installer resets the system.
Activated
The dynamic test call is activated.
Deactivated
The dynamic test call is deactivated. The "Static Test Call" dropdown selection
field appears.
Set the order in which the communication methods should be used here.
• Ethernet
1, 2, 3 or No
• PSTN
1, 2, 3 or No
• GSM
1, 2, 3 or No
• 500 ms
• 700 ms
• 900 ms
• 1100 ms
Configuration