Configuration
Type
External Siren
Internal Siren
External Strobe
Internal Strobe
Alarm Abort
Medical Alarm
Social Care
Tamper
62
Explanation
This output is activated when there is a local alarm in the
selected partition for the set siren time of the external siren.
The output does not activate for a technical alarm or hold
up alarm.
This output is activated when there is a local alarm in the
selected partition for the set siren time of the internal siren.
The output does not activate for a technical alarm or hold
up alarm.
This output is activated when there is a local alarm in the
selected partition and remains activated until the wireless
alarm panel is disarmed.
The output is also activated for 10 seconds after the
partition has been successfully armed if the EXTERNAL
strobe signal for confirmation has been activated.
This output is activated when there is a local alarm in the
selected partition and remains activated until the wireless
alarm panel is disarmed.
The output is also activated for 10 seconds after the
partition has been successfully armed if the INTERNAL
strobe signal for confirmation has been activated.
The output is activated when an alarm is interrupted by
the user in the selected partition during the possible
time period. The output is deactivated as soon as the
alarm is confirmed.
This output is activated when a medical emergency call
is triggered.
This output is activated when a social care call is
triggered.
The output is activated when the alarm panel receives
a tamper alarm from one of the following devices:
• Alarm panel (cover or wall tampering)
• Control device (cover or wall tampering)
• Zone with zone type "Tamper"
• All wireless detectors or WAM
• Sirens
The alarm panel deactivates the output as soon as the
cause of tampering has been corrected.
Can be assigned
to partitions
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes