Setting the Position Using ARMS

This section describes the method to adjust the position with the operation from control panel using
ARMS.
There are following 3 methods depending on the number of registration marks scanned. In general, the
adjustment becomes more accurate with more registration marks scanned, but it will take longer to adjust.

Adjust with 2POINTS

P.5-30
Adjust with 3POINTS
P.5-32
Adjust with 4POINTS
P.5-33
Adjust Automatically
P.5-34
Adjust Manually
P.5-36
Reference
Perform the automatic registration mark scanning with paper-weight (See "Setting Paper-Weight"
it may not scan the registration mark correctly if it is turned off.
Adjust with 2POINTS
2POINTS adjustment will scan 2 registration marks aligned in the media transportation direction, where the
adjustment is done measuring the tilting of the axis and the distance between the registration marks. This
adjustment is 1 axis adjustment (tilt adjustment).
If the loaded media is tilted as shown below, position of the scanned registration mark is shifted from the
position where it should be. Tilt and distance can be adjusted by comparing these coordinate values.