Display Issues - Christie Solaria One User Manual

Hide thumbs Also See for Solaria One:
Table of Contents

Advertisement

• Listen for a clicking noise that indicates the ballast is attempting to strike the lamp. If you do not hear a click-
ing noise, there might be a problem with the ballast. Contact a Christie accredited service technician to
resolve the issue.
• If you hear a brief clicking noise, but the lamp does not ignite, replace the lamp.
Lamp Suddenly Turns Off
• Tap Menu > Advanced Setup > Lamp Power/LiteLOC Setup. Increase the lamp power.
• Tap Menu > Status and then Interlocks in the left pane. Review and correct all interlock failures.
• Tap Menu > Status and then Temperatures in the left pane. Verify if the DMD temperatures are too high. If
the temperatures are too high, cool the projector. Ensure the projector is properly ventilated and the air filters
are not blocked.
• Replace the lamp.
LiteLOC
Not Working
• Tap Menu > Advanced Setup > LampPower/LiteLOC™ Setup. Tap Enable LiteLOC
• If the lamp power is at the maximum setting to maintain a LiteLOC™ setting, LiteLOC™ is automatically
disabled. Reduce the LiteLOC™ setting, or install a new lamp.
16.3

Display Issues

Flicker, Shadows, or Dimness
• Ensure the douser is open.
• Align the lamp. See
• Tap Menu > Advanced Setup > LampPower/LiteLOC™ Setup. Monitor the Power % field to determine
if the power is consistent or if it varies. Increase the lamp power. Lamps which are near end of service may
not operate reliably at a lower power setting.
• Fold mirror misalignment. Contact your Christie accredited service technician to resolve the issue.
• Integrator rod misalignment. Contact your Christie accredited service technician to resolve the issue.
Blank Screen, No Display of Cinema Image
• Ensure the lens cap is not on either end of the lens.
• Ensure the lamp is ON.
• Confirm all power connections are still OK.
• Ensure the douser is OPEN by verifying the state of the douser on Main panel.
• Ensure any test pattern other than the full black test pattern displays properly.
• Verify the correct display file is selected.
• For cinema connections, verify the correct port is selected.
Severe Motion Artifacts
Verify if there is a synchronization problem with reversed 3-2 pull-down in the 60Hz-to-24Hz film-to digital
conversion and correct it at the source.
16-2
Align the Lamp on page 1-18.
.