A.4 Power Requirements
A.4.1

AC Input (A)

Voltage Range
Line Frequency
Inrush Current
Current Consumption
Power Consumption
Current Rating of AC Input
Line Cord Plug Type
NOTE: Below 200VAC, when the lamp is ignited, a 25 A input surge current might occur for three seconds.
A.4.2

UPS AC Input (B)

Activation
UPS inlet connector
UPS Type
Ballast Power AC Plug Type/Current rating
(on projector)
A.5 Lamp
Type:
Power (software adjustable):
CDXL-14M
CDXL-16M
CDXL-21S1
NOTE: The ballast is power regulated and has a maximum current of 97A. Therefore the maximum power
specification for a given lamp may not be achievable until the lamp has aged, since lamp voltage increases
with hours of use.
Average Life:
CDXL-14M
CDXL-16M
CDXL-21S1
Wait time between lamp strikes
Warm up time to full brightness
NOTE: Projectors typically force a 10 minute cool down period. Ensure you do not re-strike the lamp any
sooner than 2 minutes into this cool down period since hot re-strikes reduce lamp life.
Solaria One User Manual
020-100841-02 Rev. 1 (11-2012)
(rating for powering main electronics)
200 - 240 VAC
50 Hz - 60 Hz nominal
<110 A maximum
16 A maximum (at 200 VAC)
3200 W maximum
IEC-320-C19/20 A
NEMA 6-20P
Discrete switch above the power inlet cord(s)
IEC-320-C13/10A, 240VAC
Universal 100-240VAC
IEC-320-C19/20 A
Xenon Short Arc Lamp
700W min., 1430W nom., 1575W max.
1000W min., 1600W nom., 1760W max.
1260W min., 2100W nom., 2100W max.
3500 hours
3500 hours
1500 hours
2 minutes minimum
20 minutes maximum
A-3

Advertisement

Table of Contents
loading

Table of Contents