21s - 68
MANUAL-NV3550
MANUAL-NV3550 (Continued)
Fig. 116 HOUSING BOLTS
1 - HOUSING ATTACHING BOLTS (APPLY SEALER
BEFOREHAND)
Fig. 117 SHIFT SHAFT BUSHING LOCK BOLT
1 - SHIFT SHAFT LOCK BOLT
2 - SHAFT SOCKET
(14) Lubricate then install shift shaft detent
plunger in housing bore (Fig. 118). Lubricate plunger
with petroleum jelly or gear lubricant. Verify
plunger is fully seated in detent notch in shift
shaft.
(15) Install detent spring inside plunger (Fig. 118).
(16) Install plug on detent spring and compress
spring. Then drive detent plug into transmission case
until plug seats.
(17) Install backup light switch (Fig. 119).
(18) Install input shaft snap ring (Fig. 120).
2001 JEEP WRANGLER
Fig. 118 SHIFT SHAFT DETENT PLUNGER
1 - FRONT HOUSING
2 - PLUG
3 - SPRING
4 - PLUNGER
1 - BACKUP LIGHT SWITCH
1 - INPUT SHAFT SNAP RING
Fig. 119 BACKUP LIGHT SWITCH
Fig. 120 SHAFT SNAP RING - TYPICAL
TJ