REP 9.17 Photoreceptor Seal

Parts List on PL 9.5B
WARNING
Switch off the Main Power Switch. Disconnect the
Power Cord.
Removal
1. Remove the Drum Assembly (REP 9.2).
2. (Figure 1): Remove the Right-hand Seal, the
Left-hand Seal (not shown), and the
Photoreceptor Seal.
3. Thoroughly clean the Photoreceptor Seal channel
using a vacuum cleaner.
Replacement
1. Replace the Photoreceptor Seal.
a.
Carefully fold the Photoreceptor Seal along
the perforations.
b.
Slide the Photoreceptor Seal into the
channel, smaller side up, so that the edge of
the Photoreceptor Seal forms a seal with the
inside lip of the channel.
c.
Using a soft, straight tool (a piece of
shimstock works well), carefully push the
seal into the channel, across the entire width
of the Xerographic Module.
2. Reinstall the Right-hand Seal.
a.
Insert the red stripe end of the Right-hand
Seal underneath the fold of the
Photoreceptor Seal.
b.
Install the seal fuzzy side up.
c.
Ensure that the seal is flush against the
Xerographic Module Frame.
3. Reinstall the Left-hand Seal in the same manner.
REP 9.17
Photoreceptor
Seal Channel
Photoreceptor
Seal
Figure 1. Removing and Replacing the Photoreceptor Seal
1/98
4-74
Xerographic
Module Frame
Blade
R3012KA
Retainer (3)
8830