CDM-625 Advanced Satellite Modem
Preface
Electrical Safety
The CDM-625 has been shown to comply with the EN 60950 Safety of Information
Technology Equipment (including electrical business machines) safety standard.
The equipment is rated for operation over the range 100 - 240 volts AC, or, appropriately
equipped, 36 – 60 volts DC. It has a maximum power consumption of 300 watts.
The user should observe the following instructions:
IMPORTANT
Fuses
The CDM-625 is fitted with two fuses – one each for line and neutral connections. These are
contained within the body of the IEC power inlet connector, behind a small plastic flap.
•
For 230/115 volt AC operation, use T4A, 20mm fuses.
•
For 48 volt DC operation, use T8A fuses, 20mm fuses.
FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES
WITH THE CORRECT TYPE AND RATING.
CAUTION
Environmental
The CDM-625 must not be operated in an environment where the unit is exposed to extremes of
temperature outside the ambient range 0 to 50°C, precipitation, condensation, or humid
atmospheres above 95% RH, altitudes (un-pressurised) greater than 2000 metres, excessive dust
or vibration, flammable gases, corrosive or explosive atmospheres.
Operation in vehicles or other transportable installations that are equipped to provide a stable
environment is permitted. If such vehicles do not provide a stable environment, safety of the
equipment to EN60950 may not be guaranteed.
Installation
The installation and connection to the line supply must be made in compliance to local or national
wiring codes and regulations.
The CDM-625 is designed for connection to a power system that has separate ground, line and
neutral conductors. The equipment is not designed for connection to power system that has no
direct connection to ground.
The CDM-625 is shipped with a line inlet cable suitable for use in the country of operation. If it is
necessary to replace this cable, ensure the replacement has an equivalent specification. Examples
MN-0000036 (Ref MN/CDM625.IOM)
xix
Revision 1
Need help?
Do you have a question about the CDM-625 and is the answer not in the manual?