Fimap IMx Workshop Manual page 15

Hide thumbs Also See for IMx:
Table of Contents

Advertisement

(Only B-BT) The display shows an alarm message
1) The display shows an alarm mes-
sage
The machine has a very limited working autonomy
1) The batteries connections are oxi-
dized
2) When the machine is working a bat-
tery voltage is lower and lower than
the other batteries (The difference is
bigger than 2V)
3) The battery charger is not properly
adjusted
4) The BDI (Battery Discharge Card) is
not properly adjusted
5) Batteries have been working for
several cycles
Check what alarm message is
shown and solve the related issue
by following the proper instructions
(see section
5.13.1
at page 54)
Unplug the connection wires, wash
the wire connections with water and
reconnect them protecting them with
grease.
Replace the battery with the lower
voltage.
Verify the type of battery in use and
adjust the battery charger properly
following the instructions
.
at page 50)
Verify the type of battery used on
the machine and adjust properly the
BDI.
Replace the batteries.
.
(see section
5.9
3-15